Skip to content

S Series

Multipurpose Power Line RFI Filter for Emission Control


UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet
Printer friendly version

 

S Series

  • Combines Line to Ground interference rejection filters with additional circuitry to reduce Line to Line noise and transients
  • Designed for use when equipment impedance at RF frequencies is high
  • Effective for use with switch-mode power supplies
  • Effective when used to control emissions in equipment using SCR and T2L circuits for compliance with FCC Part 15, Subpart J and EN55022, Level A, down to 150kHz

Ordering Information

Available Part Number

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

3VS1 10VS1
6VS1 20VS1
20VS6 60VS6

 

 

Specifications

Maximum leakage current, each Line to Ground:
    3 to 20 Amp 60 Amp
  @ 120 VAC 60 Hz .4 mA .75 mA
  @ 250 VAC 50 Hz .7 mA 1.25 mA
     
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 3A to 60A
   
Operating Ambient Temperature Range (at rated current Ir):
    -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematics

3, 6, 10VS

20VS

60VS

 

Case Styles
S1 (3, 6, 10A)


Typical Dimensions:
  Line/Load Terminals(4): .250 [6.3] with .07 [1.8] Dia. hole
  Ground Terminal(1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
  Mounting Holes (2): .188 [4.75] Dia.

20VS1


Typical Dimensions:
  Line/Load Terminals(4): .250 [6.3] with .07 [1.8] Dia. hole
  Ground Terminal(1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
  Mounting Slots(4): .250 x .156 [6.35 x 3.96] Dia.

20VS6

Typical Dimensions:  
  Terminals (5): 8-32
Torque 18 lbf-in. [2.03 N-m] max. ±2[..22]
  Mounting Slots(4): .250 x .156 [6.35 x 3.96] Dia.

 

 

60VS6

Typical Dimensions:  
  Terminals (5): 1/4-20
Torque 56 lbf-in. [6.32 N-m] max. ±2[..22]
  Mounting Holes (4): .218 [5.53] Dia. ± .006 [.152]

Case Dimensions

Part No. A B C D E
(max.) (max.) (max.) ± .015 (max.)
± .38
3VS1 3.36 1.82 1.16 2.375 2.78
85.3 46.2 29.5 60.33 70.6

6VS1, 10VS1 3.86 2.08 1.53 2.938 3.34
98.0 52.8 38.9 74.63 84.8

20VS1 5.23 3.38 1.53 3.75 4.20
132.8 85.9 38.9 95.25 106.7

20VS6 5.34 3.38 1.53 3.75 4.20
132.8 85.9 38.9 95.25 106.7

60VS6 7.2 3.08 2.28 5.63 6.28
182.88 78.23 57.91 142.87 158.78

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 

3VS

6VS

10VS

20VS

60VS

     
Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Current Rating Frequency - MHz
.15 .5 1 2 5 10 20 30  

3A 15 27 35 40 32 44 47 47  
6A 15 27 35 40 32 44 47 47  
10A 15 27 35 40 32 44 47 47  
20A 15 30 38 38 32 43 42 40  
60A 7 27 34 38 45 54 44 40  

 
Current Rating Frequency - MHz
.15 .3 .5 1 2 5 10 20 30

3A 35 50 65 65 65 60 50 40 45
6A 35 50 65 65 65 60 45 48 48
10A 35 50 65 65 65 60 50 40 45
20A 15 30 38 38 32 43 42 40  
60A 37 - 77 93 86 70 54 64 54

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.