Skip to content
Home > Series > Power Line > IK

IK Series

Single and 2-phase RFI Filters for Industrial Applications

 

Catalog Data Sheet
Printer friendly version

 

IK Series

  • Excellent performance for applications with high interference levels
  • Designed for single or two-phase applications
  • Wide current range
  • For small to medium sized industrial equipment, power converters and variable speed motors
  • Touch safe terminals on the 6 to 60A product provide easy connections and prevent inadvertent contact for safety in the most demanding applications

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

1IK1C 6IK1
16IK10 35IK10
50IK10 80IK10

 

 

Specifications

Maximum leakage current, each Line to Ground:
    1IK1C 6IK1 16, 35 &
50IK10
80IK10
  @120 VAC 60 Hz: 0.6 mA 0.6 mA 1.7 mA 5.2 mA
  @289 VAC 50 Hz 1.2 mA - - -
  @277 VAC 50 Hz: - 1.15 mA 3.2 mA 9.9 mA
 
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 1IK1C 6 to 80IK
  Line to Ground 289 VAC 500 VAC
  Line to Line 277 VAC 480 VAC
   
Rated Current: 1 to 80A
   
Operating Ambient Temperature Range (at rated current Ir):
    -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematic

Note 1: 1IK1C Only
Note 2: 6IK1 Only

Case Styles

1IK1C

Typical Dimensions:
  Line/Load Terminals(4): .250 [6.3] with .07 [1.8] Dia. hole
  Ground Terminal(1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
  Mounting Holes (2): .188 [4.75] Dia.

6IK1

Typical Dimensions:
  Line/Load Terminals(4): .250 [6.3] with .07 [1.8] Dia. hole
  Ground Terminal(1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
  Mounting Holes (2): .188 [4.75] Dia.

16 & 35IK10

Typical Dimensions:
  Input Terminals(3): DIN type terminal block
  Output Wire Leads (2): 7.0 [180.0] min.
  Mounting Holes (4): .216 [5.5] Dia.

 

 

 

50 & 80IK10

Typical Dimensions:
  Line/Load Terminals(4): DIN type terminal block
  Ground terminals (2): 1/4-20 screw
  Mounting Holes (4): .260 [6.5] Dia.

 

Case Dimensions

Part No. A B C D E F
(max.) (max.) (max.) ± .015 (max.) (max.)
± .38
1IK1C 3.85 2.07 1.53 2.93 3.35 -
97.8 52.6 38.9 74.4 85.1

6IK1 4.69 2.27 1.8 4.063 4.47 -
119.1 57.7 45.7 103.2 113.5

16IK10 6.28 1.97 4.76 5.90 5.35 6.34
159.5 50.0 121.0 150.0 136.0 161.0

35IK10 6.48 1.97 4.76 5.90 5.35 6.34
164.5 50.0 121.0 150.0 136.0 161.0

50IK10
80IK10
9.45 3.94 3.54 6.89 6.3 7.48
240.0 100.0 90.0 175.0 160.0 190.0

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 

1IK1C

6IK1

16 & 35IK10

50 & 80IK10

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.