Skip to content
Home > Series > PEM > GGHG

GG / HG Series

Smallest Power Entry Module with Metric Fuse Holders


UL Recognized
CSA Certified
VDE Approved

Catalog Data Sheet
Printer friendly version

 

GG Series

  • Power entry module with enhanced EMI filter
  • Single or dual fusing
  • Two element circuit provides basic attenuation
  • Available with an internal ground-circuit inductor (C versions) to isolate equipment chassis from power line ground at radio frequencies
  • Multiple termination and mounting styles

HG Series

  • Medical version of our GG Series
  • Mechanically identical to GG Series
  • Available only with dual fusing

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

General Purpose Filters
1EGG1-1 3EGG1-1 6EGG1-1 10EGG1-1
1EGG1-2 3EGG1-2 6EGG1-2 10EGG1-2
1EGG8-1 3EGG8-1 6EGG8-1 10EGG8-1
1EGG8-2 3EGG8-2 6EGG8-2 10EGG8-2
1EGS1-1 3EGS1-1 6EGS1-1 10EGS1-1
1EGS1-2 3EGS1-2 6EGS1-2 10EGS1-2
Ground Circuit Inductor
1EGG1C-1 3EGG1C-1 6EGG1C-1  
1EGG1C-2 3EGG1C-2 6EGG1C-2  
1EGG8C-1 3EGG8C-1 6EGG8C-1  
1EGG8C-2 3EGG8C-2 6EGG8C-2  
Medical Filters
1EHG1-2 3EHG1-2 6EHG1-2 10EHG1-2
1EHG8-2 3EHG8-2 6EHG8-2 10EHG8-2
1EHGS1-2 3EHGS1-2 6EHGS1-2 10EHGS1-2

 

Specifications

Maximum leakage current, each Line to Ground:
    HG Models GG Models
  @ 120 VAC 60 Hz 2 µA .25 mA
  @ 250 VAC 50 Hz
5 µA .42 mA
     
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.): 250 VAC
     
Rated Current: 1 to 10 Amps
 
   
Required Fuse(s):

5 x 20 mm
(not included)

Electrical Schematic

Warning: Do not attempt to operate a single-fused model
without the fuse door in place.

 

Accessories

GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

 

Case Styles

GG1, GG1C & HG1

Typical Dimensions:
  Mounting holes (2): .132 [3.35] Dia. with .236 [5.99] Dia. x 90°
countersink for #4 flathead screw
  Line Inlet (1): IEC60320-1 C14
  Load Terminals (2): .250 [6.3] with .07[1.8] Dia. hole
  Ground Terminal (1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot

GS1 & HGS1

Typical Dimensions:
  Line Inlet (1): IEC60320-1 C14
  Load Terminals (2): .250 [6.3] with .07[1.8] Dia. hole
  Ground Terminal (1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot

GG8 & HG8

Typical Dimensions:
  Mounting holes (2): .132 [3.35] Dia. with .236 [5.99] Dia. x 90°
countersink for #4 flathead screw
  Line Inlet (1): IEC60320-1 C14
  Wire Leads: 5.0 [127.0] Min. 18AWG, UL1015

 

 

Recommended Panel Cutouts

Typical Dimensions:
  GS / HGS panel thickness: 0.032 – 0.080 [0.81 – 2.03]
  Corner radius: 0.138 [0.35]

 

Case Dimensions

Part No. A B C D E
(max.) (max.) (max.) ± .015 (max.)
± .38
GG1 & HG1 2.15 1.13 1.29 1.417 1.76
54.5 28.7 32.8 36.0 44.7

GG1C 2.45 1.13 1.28 1.417 1.76
62.23 28.7 32.5 36.0 44.7

GS1 & HGS1 2.13 1.13 1.28 1.46* 1.42
54.0 28.7 32.5 37.08* 36.1

GG8 & HG8 2.02 1.13 1.29 1.417 1.76
51.1 28.7 32.8 36.0 44.7

* max. dimension

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
GG & GS Models

1A

3A

6A

10A

3A GG1C

6A GG1C

 

 

HG Models

1A

3A

6A

10A

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Current Rating Frequency - MHz
.01 .05 .10 .15 .5 1 5 10 30

GG/GS Models
1A 12 23 29 32 41 47 50 50 55
3A - 10 15 19 30 36 48 50 53
6A - 1 4 10 16 22 36 40 50
10A - 1 2 4 6 8 26 33 28
HG Models
1A 12 23 29 32 40 40 28 22 18
3A - 10 15 19 25 26 22 21 21
6A - 4 10 14 18 18 14 14 14
10A 1 - - 3 5 6 8 9 10

 
Current Rating Frequency - MHz
.10 .15 .5 1 3 5 10 30

GG/GS Models
1A 1 3 14 23 41 47 50 44
3A 1 2 11 14 25 38 44 40
6A 1 2 10 13 23 33 39 42
10A 4 7 17 23 - 22 43 38
HG Models
1A 2 6 19 26 30 35 35 20
3A 1 7 16 23 30 30 30 30
6A 4 7 16 23 30 30 30 30
10A - 8 16 22 - 37 43 28

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.