| Power Entry Module with Switch |
  
UL Recognized
CSA Certified
VDE Approved
15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC
Catalog Data Sheet
Printer friendly version
|
|
 |
C Series
- Two function power entry module combining a DPST switch and an IEC 60320-1 inlet
- Snap–in or flange mounting
- Available with or without a shielded general purpose or
medical grade filter
- Two element circuit provides enhanced EMI attenuation
- Reduce OEM wiring time with optional
pre–connected line and
switch terminals
Ordering Information

Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
|
|
Specifications
| Maximum leakage current, each Line to Ground: |
| |
|
F Models |
H & Unfiltered Models |
| |
@ 120 VAC 60 Hz |
.25 mA |
2 µA |
| |
@ 250 VAC 50 Hz
|
.40 mA |
5 µA |
| |
|
|
| Hipot rating (one minute): |
| |
Line to Ground |
2250 VDC |
| |
Line to Line |
1450 VDC |
| |
|
|
| Operating Frequency: |
50 / 60 Hz |
| |
|
|
| Rated Voltage |
250 VAC |
| |
|
|
| Rated Current: |
1 to 15A |
| |
|
| |
|
| Switch: |
DPST
10,000 operations at 51A max. inrush |
| |
|
| .250 Terminal Push-on Force |
18 lb / 80N |
| .188 Terminal Push-on Force |
15 lb / 67N |
Electrical Schematics
F Models

H Models

B Models

Accessories
GA400: NEMA 5-15P to IEC 60320-1 C13 line cord

|
| Case Styles |
CS, CBS

| Typical Dimensions: |
| |
Line Inlet (1): |
IEC60320-1 C14 |
| |
Terminals (6): |
.187 [4.8] with .055 [1.4] Dia. hole |
| |
Ground Terminal (1): |
.187 [4.8] with .112 x .06 [2.8 x 1.5] slot |
CE, CBE

| Typical Dimensions: |
| |
Mounting holes (2): |
.13 [3.3] Dia. with .23 [5.9] Dia. x 90°
countersink for #4 flathead screw |
| |
Line Inlet (1): |
IEC60320-1 C14 |
| |
Terminals (6): |
.187 [4.8] with .055 [1.4] Dia. hole |
| |
Ground Terminal (1): |
.187 [4.8] with .112 x .06 [2.8 x 1.5] slot |
CFS, CHS

| Typical Dimensions: |
| |
Line Inlet (1): |
IEC60320-1 C14 |
| |
Terminals (3): |
.25 [6.35] with .07 [1.8] Dia. hole |
CFE, CHE

| Typical Dimensions: |
| |
Mounting holes (2): |
.13 [3.3] Dia. with .23 [5.9] Dia. x 90°
countersink for #4 flathead screw |
| |
Line Inlet (1): |
IEC60320-1 C14 |
| |
Terminals (3): |
.25 [6.35] with .07 [1.8] Dia. hole |
|
|
CBS, CBE Pre-Connected Terminals

Recommended Panel Cutout

Panel thickness: .031 - 0.98 [0.8 - 2.5]
Not recommended for plastic panels.
Snap-in models suitable for front mounting only.
For snap-in applications, the D sides of the the cutout must
have a .02 [.508] radius on the instllation side.
Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
F |
| (max.) |
(max.) |
(max.) |
± .01 |
± .01 |
± .008 |
| ± .254 |
± .254 |
± .203 |
| CS, CBS |
1.22 |
.93 |
1.62 |
1.06 |
1.54* |
|
| 30.99 |
23.62 |
41.17 |
26.92 |
39.12* |
|
|
| CE, CBE |
1.74 |
.93 |
1.62 |
1.06 |
1.56 |
1.417 |
| 44.2 |
23.62 |
41.17 |
26.92 |
39.62 |
36.0 |
|
| CFS, CHS |
1.22 |
2.53 |
1.62 |
1.12 |
1.54* |
|
| 30.99 |
64.26 |
41.17 |
28.5 |
39.12* |
|
|
| CFE, CHE |
1.74 |
2.53 |
1.62 |
1.12 |
1.56 |
1.417 |
| 44.2 |
64.26 |
41.17 |
28.5 |
39.62 |
36.0 |
|
| * ± .000 |
| ± .008 |
|
Performance Data
| Typical Insertion Loss |
| Measured in closed 50 ohm system |
| |
1CF

|
3CF

|
6CF

|
10CF

|
1CH

|
3CH

|
6CH

|
10CH

|
 |
| Minimum Insertion Loss in dB: |
| Measured in closed 50 ohm system |
| |
|
|
| Common Mode / Asymmetrical (Line to Ground) |
|
Differential Mode / Symmetrical (Line to Line) |
|
|
|
| Current Rating |
Frequency - MHz |
| .05 |
.15 |
.5 |
1 |
5 |
10 |
30 |
|
| F Models |
| 1A |
10 |
26 |
46 |
48 |
46 |
47 |
46 |
| 3A |
8 |
16 |
32 |
36 |
43 |
48 |
50 |
| 6A |
4 |
11 |
22 |
27 |
36 |
41 |
50 |
| 10A |
1 |
4 |
14 |
18 |
27 |
33 |
42 |
| H Models |
| 1A |
16 |
21 |
37 |
44 |
26 |
21 |
10 |
| 3A |
9 |
14 |
31 |
32 |
26 |
24 |
14 |
| 6A |
4 |
10 |
22 |
23 |
19 |
18 |
13 |
| 10A |
2 |
6 |
10 |
15 |
11 |
11 |
9 |
|
|
|
| Current Rating |
Frequency - MHz |
| .05 |
.15 |
.5 |
1 |
5 |
10 |
30 |
|
| F Models |
| 1A |
1 |
3 |
13 |
28 |
62 |
67 |
42 |
| 3A |
2 |
6 |
14 |
23 |
65 |
65 |
67 |
| 6A |
2 |
6 |
14 |
27 |
46 |
48 |
58 |
| 10A |
1 |
7 |
14 |
23 |
42 |
44 |
62 |
| H Models |
| 1A |
1 |
6 |
13 |
29 |
38 |
42 |
26 |
| 3A |
1 |
5 |
10 |
22 |
36 |
34 |
36 |
| 6A |
1 |
5 |
14 |
20 |
31 |
33 |
37 |
| 10A |
1 |
4 |
11 |
19 |
32 |
37 |
38 |
|
|
|
| USA Customer Service: |
1-800-468-2023 |
| Corcom Products Direct: |
1-847-680-7400 |
| Germany: |
49-89-6089-0 |
|
|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. |