| Accessory Outlet Filter |
  
UL Recognized
CSA Certified
VDE Approved
Catalog Data Sheet
Printer friendly version |
|
 |
EBF Series
- Accessory IEC 60320-1 C13 filtered outlet
- Allows connection of accessories while filtering noise between a system and the accessory
- Enhanced performance across the frequency range
- Grounded connection
- Suitable for international usage
Ordering Information

Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
|
|
Specifications
| Maximum leakage current, each Line to Ground: |
| |
@ 120 VAC 60 Hz |
.25 mA |
| |
@ 250 VAC 50 Hz |
.50 mA |
| |
|
|
| Hipot rating (one minute): |
| |
Line to Ground |
2250 VDC |
| |
Line to Line |
1450 VDC |
| |
|
|
| Operating Frequency: |
50 / 60 Hz |
| |
|
|
| Rated voltage (max.): |
250 VAC |
| |
|
|
| Rated Current: |
1A to 10A |
| |
|
| Operating Ambient Temperature Range (at rated current Ir): |
| |
|
-10°C to +40°C |
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45
|
Electrical Schematic

|
Case Styles
EBF1

| Typical Dimensions: |
| |
Mounting holes (2): |
.132 [3.35] Dia. with .236 [5.99] Dia. x 90º
countersink for #4 flathead screw
|
| |
Load Outlet (1): |
IEC60320-1 C13 |
| |
Terminals (2): |
.250 [6.35] with .07 [1.8] Dia. hole |
| |
Ground Terminal (1): |
.250 [6.35] with .07 x .16 [1.8 x 4.1] slot |
EBF4

| Typical Dimensions: |
| |
Mounting holes (2): |
.132 [3.35] Dia. with .236 [5.99] Dia. x 90º
countersink for #4 flathead screw
|
| |
Load Outlet (1): |
IEC60320-1 C13 |
| |
Wire Leads (3): |
10.0 [254.0] min., 18AWG, UL1015 |
|
|
Recommended Panel Cutouts

Front Mount Only
Tolerance + .008 [.203] / - .000 [.000]
Case Dimensions
| Part No. |
A |
B |
C |
D |
E |
| (max.) |
(max.) |
(max.) |
± .010 |
(max.) |
| ± .25 |
| EBF1 |
2.57 |
1.33 |
1.00 |
1.575 |
1.99 |
| 65.3 |
33.8 |
25.4 |
40.01 |
50.5 |
|
| EBF4 |
2.09 |
1.39 |
1.16 |
1.575 |
1.99 |
| 53.01 |
35.31 |
29.46 |
40.01 |
50.5 |
|
|
Performance Data
| Typical Insertion Loss |
| Measured in closed 50 ohm system |
| |
| 1EBF 
|
3EBF

|
6EBF

|
10EBF

|
 |
| Minimum Insertion Loss in dB: |
| Measured in closed 50 ohm system |
| |
|
|
| Common Mode / Asymmetrical (Line to Ground) |
|
Differential Mode / Symmetrical (Line to Line) |
|
|
|
| Current Rating |
Frequency - MHz |
| .05 |
.15 |
.5 |
1 |
5 |
10 |
30 |
|
| 1A |
23 |
32 |
41 |
47 |
47 |
47 |
40 |
| 3A |
10 |
19 |
30 |
36 |
48 |
50 |
47 |
| 6A |
1 |
10 |
22 |
28 |
42 |
48 |
47 |
| 10A |
1 |
5 |
14 |
20 |
32 |
38 |
47 |
|
|
|
| Current Rating |
Frequency - MHz |
| .15 |
.5 |
1 |
3 |
5 |
10 |
30 |
|
| 1A |
3 |
14 |
23 |
41 |
47 |
50 |
44 |
| 3A |
2 |
11 |
14 |
25 |
38 |
44 |
40 |
| 6A |
2 |
10 |
14 |
20 |
33 |
42 |
40 |
| 10A |
2 |
10 |
16 |
19 |
19 |
39 |
40 |
|
|
|
| USA Customer Service: |
1-800-468-2023 |
| Corcom Products Direct: |
1-847-680-7400 |
| Germany: |
49-89-6089-0 |
|
|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. |