| DC Feedthrough Filters - Class Y4 |

Component Recognized by
UL to US and Canadian Requirements
Catalog Data Sheet
Printer friendly version |
|
 |
FFD Series
- DC feedthrough filters
- Current ratings from 10 to 200A
- Designed to meet the very stringent safety requirements of
- EN133200 class Y4 including the 2500V pulse test
- Custom versions available
Ordering Information

Filter Options / Specifications
| Capacitor ID |
Value
(nF ± 20%) |
Inductance
(nH) |
DC
Resistance
(mΩ) Max. |
| CA |
2 x 10 |
70 |
6 |
| HB |
2 x 100 |
80 |
3 |
| HD |
2 x 100 |
140 |
8 |
| NC |
2 x 470 |
90 |
2 |
| ND |
2 x 470 |
120 |
1 |
| NH |
2 x 470 |
180 |
3 |
| PK |
2 x 1000 |
240 |
2 |
| RP |
2 x 4700 |
330 |
2 |
Available Part Numbers
Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.
|
|
Specifications
| Rated voltage (max.): |
130 VDC |
| |
|
| Rated Current: |
10 to 200A |
| |
|
| Test Voltage (two seconds): |
2500 VDC |
| |
|
| Capactior Class (EN133200): |
Designed to meet Y4 |
| |
|
| Pulse Test (EN133200): |
2500V Peak |
| |
|
| Insulation Resistance
(within 1 minute): |
For C <0.33μF, R> 15000MΩ
For C>0.33μF, RC(MΩ*μF)>5000s |
| |
|
| Operating Ambient Temperature Range (at rated current Ir): |
10 to 100 Amps:
200 Amps:
|
-40°C to +60°C
-40°C to +50°C
|
| |
|
| Category Temperature Range: |
-40°C to +85°C |
| |
|
| Current Derating Above Ambient: |
|
| 10-100A: For temperature |
θ Iθ = IR √(85-θ)/25 |
| 200A: For temperature |
θ Iθ = IR √(85-θ)/35 |
| |
|
| Climatic Category: |
40/85/21 |
| |
|
| MTBF: |
Typically > 5 million hours |
| |
|
| Insulating Materials Flammability Rating: |
UL 94V-0 |
| |
|
| Case and Terminal Material / Finish: |
Nickel Plated Brass |
Schematic

|
Case Styles
| T1 - Terminal Thread |
| Part Number(s) |
Thread |
Torque
(in-lb.) |
| 10FFD6-CA/HE |
M3 |
4 |
16FFD6-CA/HE
32FFD6-CA/HE |
M4 |
11 |
| 63FFD6-HB/NH |
M6 |
22 |
| 100FFD6-NC/PK |
M8 |
44 |
| 200FFD6-ND/RP |
M10 |
70 |
|
|
|
| T2 - Mounting Thread |
| Part Number(s) |
Thread |
Torque
(in-lb.) |
10FFD6-CA/HE
16FFD6-CA/HE
32FFD6-CA/HE |
M12 x 1 |
35 |
| 63FFD6-HB/NH |
M20 x 1 |
89 |
| 100FFD6-NC/PK |
M24 x 1 |
124 |
| 200FFD6-ND/RP |
M27 x 1.5 |
142 |
|
|
Case Dimensions
| Part
Number |
A |
B |
C |
D |
E |
F |
| ± .04 |
± .02 |
±.04 |
± .04 |
± .08 |
ref. |
| 1 |
0.5 |
1 |
1 |
2 |
| 10FFD6-CA |
3.54 |
0.79 |
1.93 |
0.47 |
0.63 |
0.67 |
| 90 |
20 |
49 |
12 |
16 |
17 |
16FFD6-CA
32FFD6-CA |
3.86 |
0.79 |
2.09 |
0.47 |
0.71 |
0.67 |
| 98 |
20 |
53 |
12 |
18 |
17 |
| 63FFD6-HB |
6.30 |
0.98 |
3.70 |
0.55 |
1.02 |
0.87 |
| 160 |
25 |
94 |
14 |
26 |
22 |
| 100FFD6-NC |
7.24 |
1.26 |
4.09 |
0.63 |
1.26 |
1.06 |
| 184 |
32 |
104 |
16 |
32 |
27 |
| 200FFD6-ND |
8.23 |
1.50 |
4.41 |
0.75 |
1.57 |
1.06 |
| 209 |
38 |
112 |
19 |
40 |
27 |
| 10FFD6-HE |
5.12 |
0.79 |
3.50 |
0.47 |
0.63 |
0.67 |
| 130 |
20 |
89 |
12 |
16 |
17 |
16FFD6-HE
32FFD6-HE |
5.47 |
0.79 |
3.70 |
0.47 |
0.71 |
0.67 |
| 139 |
20 |
94 |
12 |
18 |
17 |
| 63FFD6-NH |
6.81 |
1.26 |
4.13 |
0.63 |
1.02 |
1.06 |
| 173 |
32 |
105 |
16 |
26 |
27 |
| 100FFD6-PK |
8.98 |
1.50 |
5.71 |
0.75 |
1.26 |
1.06 |
| 228 |
38 |
145 |
19 |
32 |
27 |
| 200FFD6-RP |
10.98 |
2.13 |
7.17 |
0.75 |
1.57 |
1.57 |
| 279 |
54 |
182 |
19 |
40 |
40 |
|
Performance Data
| Typical Insertion Loss in dB: |
| Measured in closed 50 ohm system |
| |
| Common Mode / Asymmetrical (Line to Ground) |
|
| Capacitor ID |
Frequency - MHz |
| 0.01 |
0.03 |
0.1 |
0.3 |
1 |
10 |
100 |
1000 |
|
| CA |
- |
- |
2 |
4 |
10 |
23 |
65 |
100 |
| HB |
2 |
4 |
10 |
18 |
27 |
62 |
95 |
100 |
| HE |
2 |
4 |
10 |
18 |
27 |
67 |
95 |
100 |
| NC |
7 |
14 |
23 |
30 |
32 |
70 |
100 |
100 |
| ND |
7 |
14 |
23 |
30 |
32 |
70 |
100 |
100 |
| NH |
7 |
14 |
23 |
31 |
35 |
75 |
100 |
100 |
| PK |
14 |
21 |
30 |
34 |
53 |
75 |
100 |
100 |
| RP |
20 |
32 |
40 |
52 |
85 |
100 |
100 |
100 |
|
|
|
| USA Customer Service: |
1-800-468-2023 |
| Corcom Products Direct: |
1-847-680-7400 |
| Germany: |
49-89-6089-0 |
|
|
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. |