Skip to content
Home > Series > DC > DCP

DCP Series

The CHAMELEON Adaptable Module for DC Applications


UL Recognized
CSA Certified
TUV Approved

Catalog Data Sheet
Printer friendly version

 

DCP Series

  • Full flexibility of design in the most compact package
  • General purpose designed for DC applications
  • Mates with a standard MOLEX* connector (HCS Series) which prevents accidental connection to AC Power

*MOLEX is a trademark of MOLEX Incorporated

Ordering Information

 

 

Specifications

Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Rated voltage (max.): 80 VDC
     
Rated Current: 3 to 10A
   
Fuseholder: Accepts one or two fuses
.25" x 1.25" (not included)
or 5 x 20mm (not included)
   
Terminals: .187 x .032 [4.8 x .81] terminal tabs
Recommended for use with mating connector, no solder
 
Operating Ambient Temperature Range (at rated current Ir):
  -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

Electrical Schematic

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

PE000DD3D PS000DD3D
PE000DD6D PS000DD6D
PE000DDXD PS000DDXD
PE000SD3D PS000SD3D
PE000SD6D PS000SD6D
PE000SDXD PS000SDXD

 

Case Styles

PE

PS

Accessories

GA210 - (shown above) Pre-assembled connector housing with two 36" long 18 gauge wires to mate with P Series DC filters

MOLEX* Component Numbers:

03-12-1026: Connector housing to mate with DCP Series
18-12-1222: Female Terminal (2 needed per housing)

*MOLEX is a trademark of MOLEX Incorporated

 

 

 

Recommended Panel Cutouts

Note: The external edges (installation side) on the "D" sides of the cutout should have a minimum .020" radius. For optimal retention against extraction, the corresponding inner edge should be sharp, without paint or coatings. Edge coatings, including anodization are also discouraged for good shield contact.

Case Dimensions

Part No. A B C D E F
(max.) (max.) (max.) * see Note * see Note (ref.)
PE 1.98 2.13 2.31 1.12 2.201 1.575
50.29 54.10 58.67 28.45 55.91 40.0

PS 1.24 2.13 2.31 1.06 2.201  
31.50 54.10 58.67 26.93 55.91  

*+.008 [.201] / -.000 [.000]

 

Performance Data

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Current Rating Frequency - MHz
.03 .1 .15 .5 1 3 5 10 30

3A 7 17 21 27 33 40 44 50 32
6A - 8 12 17 23 32 36 44 30
10A - 3 5 10 13 23 27 35 27

 
Current Rating Frequency - MHz
.10 .15 .5 1 3 5 10 30  

3A 2 4 12 15 30 48 50 45  
6A 2 4 12 15 22 42 55 45  
10A 2 4 12 15 22 42 55 45  

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.