FCD Series

Three Phase External Power Line Filter for Frequency Converters


UL Recognized
CSA Certified

Catalog Data Sheet
Printer friendly version

 

FCD Series

  • Suitable to meet the latest EMC standards
  • Insulated safety terminals
  • Suitable for EMC troubleshooting in the field
  • Very high attenuation
  • High insertion loss
  • BS models optimized for very high insertion loss
  • BS models suitable for infeed/regenerative (ER) applications
  • Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications

Ordering Information

Available Part Numbers

Click on any part number for 3D CAD models, customer drawings, distributor stock status and eCommerce Links.

Dual Stage Single Stage Hi-Performance
6FCD10 12FCD10B 50FCD10BS
16FCD10 16FCD10B 80FCD10BS
25FCD10 25FCD10B 110FCD10BS
36FCD10 36FCD10B 150FCD10BS
50FCD10 50FCD10B 150FCD10BS-95
  80FCD10B 180FCD10BS
  110FCD10B 230FCD10BS
  150FCD10B  
  150FCD10B-95  
  180FCD10B  
  230FCD10B  

 

 

Specifications

Maximum leakage current voltage drop to virtual N to PE/V:
  6FCD10 .26 mA/V
  12 & 16FCD10 .45 mA/V
  25, 36 & 50FCD10 .52 mA/V
  12 & 16FCD10B .46 mA/V
  25 & 36FCD10B .52 mA/V
  50FCD10B .57 mA/V
  80 & 110FCD10B .62 mA/V
  150FCD10B .63 mA/V
  180 & 230FCD10B .92 mA/V
  50, 80, 110, 150, 180 & 230 FCD10BS 3.25 mA/V
     
Hipot rating (one minute):
  Line to Ground 2250 VDC
  Line to Line 1450 VDC
     
Operating Frequency: 50 / 60 Hz
     
Rated voltage (max.):  
  Phase to Phase 480 VAC
  Phase to Neutral / Ground 277 VAC
     
Rated Current: 6A to 230A
   
Operating Ambient Temperature Range (at rated current Ir):
  -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir √(85-Ta)/45

 

 

 

Electrical Schematics

6FCD10

12 to 50A FCD10

12 to 50A FCD10B

 

 

80 to 230A FCD10B

FCD10BS

Case Styles

6 to 50A FCD10 & FCD10B

 

80 to 150A FCD10B
50 to 150A FCD10BS

180 to 230FCD10B/BS

 

 

 

Case Dimensions

Part No. A B C D E F
(max.) (max.) (max.) (ref.) (max.) (ref.)
6FCD10 6.18 4.33 2.32 3.74 5.16 2.76
157.0 110.0 59.0 95.0 131.0 70.0

12FCD10/10B
16FCD10/10B
6.97 5.51 2.56 4.92 5.94 2.76
177.0 140.0 65.0 125.0 151.0 70.0

25FCD10/10B
36FCD10/10B
50FCD10/10B
9.69 6.26 2.52 5.71 8.43 4.53
246.0 159.0 64.0 145.0 214.0 115.0

50FCD10BS 11.41 6.61 3.54 6.10 8.70 4.53
290.0 168.0 90.0 155.0 221.0 115.0

80FCD10B/BS
110FCD10B/BS
150FCD10B/BS
12.09 6.61 5.55 6.10 8.70 4.53
307.0 168.0 141.0 155.0 221.0 115.0

150FCD10B-95
150FCD10BS-95
12.6 6.61 5.55 6.10 8.70 4.53
320.0 168.0 141.0 155.0 221.0 115.0

180FCD10B/BS
230FCD10B/BS
15.71 6.61 5.55 6.10 11.81 6.50
399.0 168.0 141.0 155.0 300.0 165.0

Terminals

Part No. Terminal Size Torque max.
lbf-in [N-m]

6FCD10 Ground 8-32 20.7 [2.34]
Line / Load 4mm²
terminal block
7.08 [0.8]

12FCD10/10B
16FCD10/10B
Ground M5 26.58 [3.0]
Line / Load 4mm²
terminal block
7.08 [0.8]

25FCD10/10B
36FCD10/10B
Ground M5 26.58 [3.0]
Line / Load 6mm²
terminal block
15.93 [1.8]

50FCD10/10B Ground M5 26.58 [3.0]
Line / Load 10mm²
terminal block
15.93 [1.8]

50FCD10BS Ground M10 88.5 [10.0]
Line / Load 16mm²
terminal block
20.36 [2.3]

80 to 150FCD10B
80 to 150FCD10BS
Ground M10 88.5 [10.0]
Line / Load 50mm²
terminal block
70.80 [8.0]

150FCD10B/BS-95
180FCD10B/BS
230FCD10B/BS
Ground M10 88.5 [10.0]
Line / Load 95mm²
terminal block
177.0 [20.0]

 

Performance Data

Typical Insertion Loss
Measured in closed 50 ohm system
 

6FCD10

12FCD10

16FCD10

25FCD10

36FCD10

50FCD10

12FCD10B

16FCD10B

25FCD10B

36FCD10B

50FCD10B

80FCD10B

110FCD10B

150FCD10B

180FCD10B

230FCD10B

50, 80 & 110FCD10BS

150FCD10BS

180FCD10BS

230FCD10BS

Minimum Insertion Loss in dB:
Measured in closed 50 ohm system
     
Common Mode / Asymmetrical (Line to Ground)   Differential Mode / Symmetrical (Line to Line)

 
Model Frequency - MHz
.01 .03 .05 .1 .5 1 5 10 30

6FCD10 2 14 23 39 56 52 48 45 33
12 & 16FCD10 13 30 36 45 75 75 52 45 35
25FCD10 13 30 36 45 75 75 52 45 35
36FCD10 9 26 32 40 75 75 52 45 35
50FCD10 9 26 32 40 75 75 52 45 35
12FCD10B 18 45 59 75 73 65 49 47 26
16FCD10B 18 45 59 75 73 65 49 47 26
25FCD10B 18 45 60 49 83 75 58 56 28
36FCD10B 8 38 52 70 77 70 54 50 47
50FCD10B 3 34 49 67 76 70 59 58 37
80FCD10B 2 35 49 67 74 67 59 58 27
110FCD10B 2 35 49 66 72 65 59 58 18
150FCD10B 1 36 50 66 69 63 59 58 9
180FCD10B - 36 50 66 67 60 59 58 -
230FCD10B - 25 40 58 73 66 58 52 21
50FCD10BS 40 66 70 69 65 60 53 51 24
80FCD10BS 35 63 67 66 63 58 52 49 23
110FCD10BS 30 61 69 69 66 60 53 53 25
150FCD10BS 32 61 67 67 62 56 48 46 16
180FCD10BS 30 60 65 65 61 55 47 46 16
230FCD10BS 27 58 62 63 59 54 46 45 15
 
Current Rating Frequency - MHz
.01 .03 .05 .1 .5 1 5 10 30

6FCD10 9 8 24 40 62 57 50 48 38
12 & 16FCD10 9 13 24 55 75 75 75 65 60
25FCD10 9 13 26 55 75 75 75 65 60
36FCD10 9 13 26 46 75 75 75 65 60
50FCD10 9 13 26 46 75 75 75 65 60
12FCD10B 6 13 9 37 90 86 74 78 34
16FCD10B 6 13 9 37 60 86 74 78 34
25FCD10B 10 16 12 41 89 87 69 86 43
36FCD10B 17 24 24 38 87 81 63 66 24
50FCD10B 15 24 27 21 88 74 51 69 52
80FCD10B 17 25 28 23 87 71 50 62 45
110FCD10B 18 27 30 25 86 69 49 56 39
150FCD10B 19 28 31 28 85 66 49 49 32
180FCD10B 21 29 33 30 84 63 48 43 23
230FCD10B 22 31 35 36 78 60 46 41 26
50FCD10BS 25 31 26 59 73 64 50 45 19
80FCD10BS 25 31 26 59 73 64 50 45 19
110FCD10BS 24 31 24 55 72 65 51 46 26
150FCD10BS 25 33 32 51 71 61 47 42 22
180FCD10BS 25 33 32 51 71 61 47 42 22
230FCD10BS 25 33 32 51 71 64 47 42 22

 

 

USA Customer Service: 1-800-468-2023
Corcom Products Direct: 1-847-680-7400
Germany: 49-89-6089-0
  Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.